    bendaireboy
    Participant

    Hi guys has anyone got any idea with this dryer which had a open circuit heater ,which has been replaced,it now works when it feels like it ie: heats on some but not all progs,I have cleaned sensors but still messes about any help would be appreciated thanks,Nige

    #426655
    Seamy
    Participant

    Re: beko condensor dryer dcu8230

    Did you fit the correct heater? Also check the condenser is not clogged, sensor bars not covered in fluff giving error readings. NTCs on heaters on these are always going down to earth, test it on M’ohm scale for low resistance to earth.

    #426656
    bendaireboy
    Participant

    Re: beko condensor dryer dcu8230

    cheers Seamy,correct heater fitted condenser cleaned before new heater fitted as I think that was original cause,and sensor bars cleaned as I saw on post here somewhere a while back that f/c could cause this type of fault but thanks for you helpful input as usual

    #426657
    bendaireboy
    Participant

    Re: beko condensor dryer dcu8230

    update we have changed p.c.b and was heating when tested customer subsequently used on Jean prog with one item,no or little heat,do you think this is not enough clothing for sensor to sense,any help appreciated nige

    #426658
    Seamy
    Participant

    Re: beko condensor dryer dcu8230

    Yeah, best to use a timed setting if only using small load.