Called out to this machine as it was stopping on cycle.went through all the usuals,including insulation testing heaters.Found motor armature leaking to earth but just under house trip level.fitted new motor but fault persists.
Programme cottons runs and stops with 39 in the display which i assume is minutes left.
Drum is warm,pumped out.all water valves areok,motor pump and heaters ok.
Is there a diagnostic programme on this machine,if so how to access.what would the machine be wanting to do at 39 mins, i dont have a map of the cycle.the pressure appears clear when blown through. Ideas welcomed. Steve