    RHrepairs
    Participant

    Have a Siemens dryer WT36V395GB/16 FD9211 here and the machine stops after 3mins and the filter/hose light comes on. Put my ampmeter on to it and its pulling just over 3amps when on. So anyone got any idea? Or does anyone have the diagnostic test for this appliance so i can pull up a fault code.
    Thanks

    #429827
    Martin
    Participant

    Re: Siemens Vented dryer IQ300 stops after 3mins filter ligh

    Front NTC

    #429828
    RHrepairs
    Participant

    Re: Siemens Vented dryer IQ300 stops after 3mins filter ligh

    Thanks Martin

    #429829
    RHrepairs
    Participant

    Re: Siemens Vented dryer IQ300 stops after 3mins filter ligh

    There is no front ntc is this appliance…so could it be the heater or board?

    #429830
    Martin
    Participant

    Re: Siemens Vented dryer IQ300 stops after 3mins filter ligh

    The fault indicative of an NTC fault or an airflow restriction somewhere (fluff block in heater box or exhaust through the wall) causing the NTC to close the programme down.

    I think it neither a fault with the heater or the board at this stage TBH.