indesit IDF125 pumps out all the time even with machine off

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries indesit IDF125 pumps out all the time even with machine off

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #86371
    alro
    Participant

    Hi gents help needed IDF125 no flashing lights just pumps out allthe time i did manage to do a rapid wash rebuilt it sides back on turned machine off then the pump came on. only way to stop pump is to open door or turn off at plug any help please cheers alro

    #430910
    stevebunyan
    Participant

    Re: indesit IDF125 pumps out all the time even with machine

    Hi
    You have water in the base which has activated the anti flood float.

    #430911
    iadom
    Moderator

    Re: indesit IDF125 pumps out all the time even with machine

    stevebunyan wrote:Hi
    You have water in the base which has activated the anti flood float.

    Which ‘should’ have activated an error code and been visible when alro had the sides off.

    #430912
    alro
    Participant

    Re: indesit IDF125 pumps out all the time even with machine

    no water in base had sides off pump runs for 6 min then stops select any prog pump runs for ever till i open door or turn off at wall any help please or tech imfo cheers alro

    #430913
    iadom
    Moderator

    Re: indesit IDF125 pumps out all the time even with machine

    Found a copy of the manual, check your inbox.

    Jim.

Viewing 5 posts - 1 through 5 (of 5 total)