hotpoint HVL241 error Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › hotpoint HVL241 error This topic has 3 replies, 2 voices, and was last updated 10 years, 4 months ago by wilf. Viewing 4 posts - 1 through 4 (of 4 total) Author Posts November 24, 2015 at 2:30 pm #86794 wilfParticipant cant find any error code reference for these of the four vertical lights the second flashes and valve pulses on fill. empties and spins ok heater and air circuit tests ok no earth faults. I’m thinking board any ideas? thanks wilf November 24, 2015 at 2:54 pm #433050 iadomModerator Re: hotpoint HVL241 error Pressure switch stuck on empty, check pressure switch then module. PM me an email address and I will send you the manual. Jim. November 24, 2015 at 3:34 pm #433051 wilfParticipant Re: hotpoint HVL241 error thanks pressure switch is anlogue and I can hear it working when blown havnt got one to try with but I didnt meter it but got a positive click. wilf November 24, 2015 at 4:20 pm #433052 iadomModerator Re: hotpoint HVL241 error There is more info in the manual. 😉 Author Posts Viewing 4 posts - 1 through 4 (of 4 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In