Like the enquiry of a couple of years ago , i to have one that will not switch on pump and condenser valve on drying cycle. stats , heater, wiring all ok. Have fitted a new main pcb , still the same. any ideas ? Bendy.
not had a pump problem but had a few that would not turn on valve
found a work around but not the fault
set dryer cycle and start it
wait 10 secs or so till cycle starts
turn machine off at the plug
wait till machine stops and all lights go off
then switch socket back on
I found water valve then came on and machine works dryer normally
Dodgy edge connector on that module ??
Take each one off and check individual pins etc try a contact cleaner in case oxydised
Sounds like a shared nuetral failing intermittantly