Beko American F/F GNEV221APB Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Beko American F/F GNEV221APB This topic has 2 replies, 2 voices, and was last updated 9 years, 10 months ago by Alanj. Viewing 3 posts - 1 through 3 (of 3 total) Author Posts May 26, 2016 at 9:40 am #88396 AlanjParticipant Hi Guys, customer has called to say fridge is icing up through the vents. Freezer is working ok. Anyone know what is causing this to happen and how to cure it. I’m not really keen on these American style appliances but would like to fix it. Thanks Alan May 26, 2016 at 9:45 am #437934 SAMURIParticipant Re: Beko American F/F GNEV221APB Check the fan is working that is the most common fault is the fan has failed. The fan only runs with the door closed so press the light switch to test if the fan works. It does have a short delay for the fan to cut in after holding the switch down. Bob May 30, 2016 at 7:59 pm #437935 AlanjParticipant Re: Beko American F/F GNEV221APB Thanks Bob, will check it out 🙂 Author Posts Viewing 3 posts - 1 through 3 (of 3 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In