    Participant

    customer called about this dryer,found filter blocked,pump housing blocked.all cleaned out.still seems to bring filter and water lights on after 6 minutes.also getting seems to be getting to hot,any ideas richard. 🙁

    #438390
    electrofix
    Moderator

    Re: beko dcu 7230

    if its getting too hot there is not much it can be

    there a 2 thermistors. 1 is part of the element the other is at the front by the filter

    other than that is airflow or board

    will pm some info

    Dave

    #438391
    Alanj
    Participant

    Re: beko dcu 7230

    I have one of these not heating. I called yesterday and found condenser clogged up, cleaned it up and tried it. Seemed to be heating fine but customer called today to say it wasn’t heating.
    Thermistor on heater reads 4.4kohm? Any idea if that is correct reading? No power coming to heater plug, could this be the board or one of the thermistors?

    Alan
    DCU7230W 7182681500. S/N 15-203276-02

    #438392
    electrofix
    Moderator

    Re: beko dcu 7230

    element has an overheat stat that may have tripped

    sent you some info by pm

    Dave

    #438393
    eng14
    Participant

    Re: beko dcu 7230

    thanks dave

    #438394
    Alanj
    Participant

    Re: beko dcu 7230

    Have checked heater trip. It is ok, that’s why I asked about thermistor resistance.

    Alan