Hi all need some advice on this one , F 01{e5d1b7155a01ef1f3b9c9968eaba33524ee81600d00d4be2b4d93ac2e58cec2d} on display under fridge temp , fridge is warm freezer is fine -21 , the air flap is stuck closed in the fridge not letting cold air in , any ideas thanks Kieran
Martin wrote:I truly don’t know the answer Kieran but I suspect you’ve answered it yourself, that air flap. 😉
Hi Martin , ive seen 2 more of these since same fault flap iced up so it stays closed , i dont know what part to replace doesnt look like anything is wrong with the motor for the flap any ideas
??thanks
If the flap is iced up you will need a diffuser plus check to ensure that the fridge door is closing properly as that is the usual cause (allowing warm air into the fridge )