    My BEKO DW686 is displaying Er3 error code.Help please.

    #439790
    electrofix
    Moderator

    Re: DW686 Er3

    error 3 comes up as a heater fault

    Dave

    #439791
    Phil Thompson
    Participant

    Re: DW686 Er3

    Checked the heater, it’s working OK. Problem appears to be no water circulation while it’s heating. Circulation pump is not stuck but I’m unable to test the motor as it has two plugs with two wires each and contains a PCB, not just a case of applying 240v to it.

    #439792
    electrofix
    Moderator

    Re: DW686 Er3

    from the pictures i have found motor has 2 plugs

    plug 1 has 3 connections
    plug 2 has 2 connections

    plug 1 supplies power
    plug 2 is data to the main board

    i do not know what voltage the motor runs at so cannot confirm what voltage you will find at the connections
    there are only 2 possibilities here either A the motor is not being turned on or B the motor is faulty

    Dave

    #439793
    Phil Thompson
    Participant

    Re: DW686 Er3

    With the door shut and the heater working plug 1 on the circulation motor has permanent live on the brown wire and switched neutral on the purple wire. Plug 2 has brown and black wires which connect to the user control board. Does the motor not run because it is requiring a control input from the user control board? I’ve examined the user control board and all looks good. No real way of progressing this without buying either the motor or the control board.

    #439794
    electrofix
    Moderator

    Re: DW686 Er3

    got it wrong plugs are the other way round

    but

    if the heater is on motor must be

    not a lot of tech info on this motor so cant help a lot