Siemens Dryer cuts out 5 minutes

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Siemens Dryer cuts out 5 minutes

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #89146
    pmb
    Participant

    Siemens vented Dryer, stops after 5 minutes and lights flash.
    Suspect sensor 600157 or NTC 613753 on the front.
    Could I have fitted a hotpoint NTC to see if it worked ?
    Airflow is low but assume it’s normal for Siemens because there
    Are no blockages.

    #440483
    kaibart
    Moderator

    Re: Siemens Dryer cuts out 5 minutes

    On Bosch and Siemens vented dryers the vent hose has to be 600mm before a bend and airflow is key on these the ntc is located behind the bottom left plastic cover so it’s easy to check,hope this helps kai

    #440484
    pmb
    Participant

    Re: Siemens Dryer cuts out 5 minutes

    Tried NTC did not work, so now ordering Sensor.
    Should have ordered both straight off.

Viewing 3 posts - 1 through 3 (of 3 total)