bosch wae24060

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #89261
    mikehha
    Participant

    hi all
    This is just a quick one. changed the heater in this m/c because it had blown and taken out the 13a fuse now the m/c over heats my question is could the element blowing have taken the board out as well.or could it have been the other way around.

    #440842
    Kentish
    Participant

    Re: bosch wae24060

    The elements in Bosch now are no better than anyone else now. Unlikely the PCB will have caused the element to fail, more the other way around. I will though say that although I have had to change quite a few Bosch elements for being to earth, I haven’t had one thats caused further issues…..yet anyway:)

    #440843
    kaibart
    Moderator

    Re: bosch wae24060

    Have you checked the ntc also all new Bosch washers are now fitted with 10amp fuses odd but they are

    #440844
    mikehha
    Participant

    Re: bosch wae24060

    what ohms reading should I be getting across the ntc at room temp. Have you ever had a ntc fail

    #440845
    kaibart
    Moderator

    Re: bosch wae24060

    Not on a Bosch but they are part of the earthing should be around 28k ohms

Viewing 5 posts - 1 through 5 (of 5 total)