Bosch SMV69T10GB/16 error lights

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Bosch SMV69T10GB/16 error lights

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #89297
    smeghead
    Participant

    After power on ,then pressing start, Tap & Rinse light flash- have checked inlet valve (ok), no water in base, no error number , just these lights flash.
    Any Clues ??
    Thanks Clive.

    #440945
    Martin
    Participant

    Re: Bosch SMV69T10GB/16 error lights

    E20 Heat pump fault. 🙁

    #440946
    smeghead
    Participant

    Re: Bosch SMV69T10GB/16 error lights

    thanks Martin, Heater tests ok- so do you mean Pump part?
    Not sure of motor resistance- any ideas.

    #440947
    Martin
    Participant

    Re: Bosch SMV69T10GB/16 error lights

    smeghead wrote:thanks Martin, Heater tests ok- so do you mean Pump part?
    Not sure of motor resistance- any ideas.

    The flashing LED’s refers to a Heatpump error is all I know so make of that as you will. However the motor resistance is 41.5 ohms or 53.5 ohms dependent on the winding manufacturer (taken from the less than specific manual) 😕

    Cr ap machine, cr-ap manual. 😡

    #440948
    nomadPaul
    Participant

    Re: Bosch SMV69T10GB/16 error lights

    Ok , I have had this once , recently , and even though the fault code was e20/e21 , it turned out to be the heat exchanger inlet valve.

    #440949
    smeghead
    Participant

    Re: Bosch SMV69T10GB/16 error lights

    Cheers for the feedback chaps.
    Will go back & do some more tests.
    I did check the valve on the lhs tank, but couldn’t get to the contacts on the valve at the front of the chamber.
    Maybe take a heat pump with me as well.