White knight dryer Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › White knight dryer This topic has 2 replies, 2 voices, and was last updated 9 years, 3 months ago by kaibart. Viewing 3 posts - 1 through 3 (of 3 total) Author Posts December 15, 2016 at 9:16 pm #90129 kaibartModerator Hi having a issue with 85aw 0312 85a 15000 no heat change heater check reset stat exhaust stat check brush on drum fine changed module still the same, ( faulty new pcb maybe) anyone got any ideas. Kai December 15, 2016 at 10:25 pm #443801 electrofixModerator Re: White knight dryer there are 3 stats. 2 round the heater and exhaust long shot is wiring from heater correct there is normally a spare terminal and i have seen wires placed wrong white night are good and have hidden resources if you know where to look. below is wiring and part manual http://www.whiteknightrange.co.uk/service-manuals/ also did you try wet clothes as its a sensor dryer Dave December 16, 2016 at 7:00 am #443802 kaibartModerator Re: White knight dryer Cheers dave Author Posts Viewing 3 posts - 1 through 3 (of 3 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In