AEG washer Dryer – no heat on dry Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › AEG washer Dryer – no heat on dry This topic has 2 replies, 2 voices, and was last updated 9 years, 3 months ago by trotter. Viewing 3 posts - 1 through 3 (of 3 total) Author Posts December 16, 2016 at 10:44 am #90138 trotterParticipant PNC 914605004(00) Dec 2009 No live supply to dryer heater, all ‘stats and cut outs look ok ….I’m guessing dryer board? Any thoughts appreciated. December 16, 2016 at 2:15 pm #443835 MartinParticipant Re: AEG washer Dryer – no heat on dry trotter wrote:No live supply to dryer heater, all ‘stats and cut outs look ok What of the Dryer temp sensor (NTC) at the base of the condenser? (Should read 5000? @ 25C) December 19, 2016 at 7:51 am #443836 trotterParticipant Re: AEG washer Dryer – no heat on dry Tried that Martin – but thanks!! Went back on Saturday with a new dryer board and all ok now :-))) Author Posts Viewing 3 posts - 1 through 3 (of 3 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In