    electrofix
    Moderator

    don’t do many FF but got landed to look at this one just on Christmas

    Admiral 859510115000 11 0713 001798

    customer complained the fridge was freezing. so I realised the control door was not closing when it came to temp. removed motor unit inside fridge and found previous repair by some idiot that must have put it back wrong, put a screw through 2 of the cables and butt jointed them.
    don’t know the exact history as this house is tenanted so don’t know when that repair was done. inspected PCB and found a blown triac ( see picture)

    anyone got any wiring info to find what this triac feeds. is that my problem and if so do motorised flaps fail on these

    thanks

    Dave

    #444307
    Grendal
    Participant

    Re: Admiral fridge freezer

    Hi that machine is a standard Whirlpool side by side. The baffles do fail on those plus I have had the solenoid on the ice maker (The 1 inside the freezer compartment ) go faulty causing the board to blow on quite a few occaisions.

    #444308
    electrofix
    Moderator

    Re: Admiral fridge freezer

    Thanks Grendal

    have ordered a triac but will have to go back and meter out the cables if no one has any wiring info. would be nice to know where the 6 wires in the plug go without having to meter them all

    Dave