Hotpoint WMUD 843 BC Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Hotpoint WMUD 843 BC This topic has 2 replies, 2 voices, and was last updated 9 years, 2 months ago by tash. Viewing 3 posts - 1 through 3 (of 3 total) Author Posts January 23, 2017 at 1:03 pm #90402 tashParticipant this washer displays fo5 .. checked draining pump etc an ps/switch hose all ok.. it spins through full spin then with one min left it fills for a few seconds drains off again then code comes up..weird January 23, 2017 at 5:46 pm #444668 kaibartModerator Re: Hotpoint WMUD 843 BC Have you checked the heater and ntc low insulation can cause problems if ok I would look at the main module 😕 January 23, 2017 at 6:54 pm #444669 tashParticipant Re: Hotpoint WMUD 843 BC cheers Author Posts Viewing 3 posts - 1 through 3 (of 3 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In