hotpoint TCYM750C Pump wont run

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries hotpoint TCYM750C Pump wont run

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #90500
    delta01
    Participant

    hi i have tested all components in the pump housing all are ok the float is operating correctly the micro switch is ok as is the pump only thing i can think is timer
    has there been an issue with that thanks John

    #445003
    delta01
    Participant

    Re: hotpoint TCYM750C Pump wont run

    found fault eventually the grey lead back to timer o/c due to drum wearing the insulation away

Viewing 2 posts - 1 through 2 (of 2 total)