Hoover WDYN656D

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #90520
    rolf
    Participant

    Hello.
    Has anyone got a test procedure for a Hoover WDY656D. 31005850
    The problem is I select programme the door locks and it will do nothing else, IR fine. I suspect the module but any other pointers appreciated.

    #445077
    kaibart
    Moderator

    Re: Hoover WDYN656D

    Do a insulation test some of the tri phase modules are earthed and more than likely the module if you get it in to test it will do exactly the same

    #445078
    rolf
    Participant

    Re: Hoover WDYN656D

    Thanks Kaibart , IR reading is fine over a thousand meg. It’s binned now anyway she didn’t want to wait for parts. Customers eh, but thanks again for your advice.

Viewing 3 posts - 1 through 3 (of 3 total)
  • You must be logged in to reply to this topic.