Bosch WTA74100GB/09

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #91206
    1totalshambles
    Participant

    Hi. This months problem I need a bit of advice on.
    This Bosch vented t/dryer sometimes does not dry the clothes apparently which I notice looking at customer reviews seems to crop up as a problem with these, trouble is noone has the answer.
    What I know: well I know that it heats, I know too that it is cycling hot then warm then hot on the t/stat if set on timed heat- by placing a hand across the vent-, that the heating element and its two bullet stats are ok. What I don`t know is whether the ntc sensor on the element is ok which might only be relevant if set on cupboard, and such like, automatic dry programmes which has not been tested because no handy damp load available. The pcb seems to be doing its stuff.
    Are there any common failing on the machine such as the ntc sensor or anything else that I may have missed?
    Anyone any ideas please. Thanks.

    #447411
    kaibart
    Moderator

    Re: Bosch WTA74100GB/09

    The rear ntcs do fail airflow is key on these Bosch dryers make sure the vent hose has a straight run of as least 450mm before a bend in the hose or this will definitely cause issues kai

    #447412
    1totalshambles
    Participant

    Re: Bosch WTA74100GB/09

    Thanks I`ll give the thermistor a go since the vent hose is perfect.

Viewing 3 posts - 1 through 3 (of 3 total)