Fagor FWM714IT overfilling

Viewing 1 post (of 1 total)
  • Author
    Posts
  • #91224
    aqua_serve
    Participant

    Hi guys,

    I went out to a FWM714IT today with an F07 fault (overfill/drain). It’s an integrated machine but with how the plumbing has been installed I’m unable to pull the machine out without placing a lot of stress on the hoses or worse still the inlet valve.

    Having looked at things to check I’ve been able to test the pump which checks out fine, the machine visually overfills too. The list of other components include the pressure switch and a level sensor (???). Does this machine have a separate level sensor or does it use the pressure switch? I’ve got a feeling I’m going to have to go in and tear the machine out of it’s position but wouldn’t mind going armed with the correct spare. Obviously I appreciate it could be a wiring issue. Any thoughts appreciated?

    Mark

Viewing 1 post (of 1 total)
  • You must be logged in to reply to this topic.