neff s51m53x0gb/16

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #92099
    eng14
    Participant

    hi all,this d/w will work on quick wash but fills and empties on the rest.they say a reed was fitted by another engineer. 😕

    #450271
    Martin
    Participant

    Re: neff s51m53x0gb/16

    The water inlet chamber may need replacing if the flow meter impeller is sticking, one possibility.

    No water in the base, yes/no?

    Heat pump gunged up can give random E:14 errors. 🙁

    #450272
    eng14
    Participant

    Re: neff s51m53x0gb/16

    no water in base,will check chamber.thanks.

    #450273
    eng14
    Participant

    Re: neff s51m53x0gb/16

    thanks chamber blocked.