    keithwilliams
    Participant

    good evening
    bad day at the office today. normally get most dishies running no probs but this guy runs beautifully but doesnt heat and there are no error codes at all. i have of course checked the heater and the wiring to it. running it with panel loose and voltmeter on the board, theres no voltage coming out to heater. i accept that the board is suspected but any idea which components to have ago at/ this is not the normal smeg board with the big caps on.

    or is there any other possible contributor to this. its spraying good and water level is correct.

    thanks
    k

    #450554
    electrofix
    Moderator

    Re: adp8912 smeg not heating.

    have you checked heater relay. most of them are a 12 dc coil ( look on relay) you could solder a couple of wires and see if you get a voltage

    Dave

    #450555
    keithwilliams
    Participant

    Re: adp8912 smeg not heating.

    hi thanks for the reply.
    yes i replace quite a few relays. the coil is okay but i think ill open it up for a look and solder a new one in regardless.

    i will let you know what outcome is

    thanks
    k

    #450556
    keithwilliams
    Participant

    Re: adp8912 smeg not heating.

    applying a 12volt battery to coil the relay was clicking but not switching. soldered in a new relay and job done.

    once again many thanks
    k