    hello all anyone come across the unit it is twin faned the fault is its frozen solid iam asuming the sensors gone but couldnt check it as its so frozen up so if anyone can help will save me 1 revisit thanks. stu

    #133110
    Dave_Conway
    Participant

    Re: scandinova uff 238w

    I’ve no idea who made this one for Comet, and all they list is a bulb for it 😕

    It’s not a Brandt (for a change).

    Anyone know ?

    Welome to the site by the way Stu 😉

    Dave.

    #133111
    Penguin45
    Participant

    Re: scandinova uff 238w

    Scandinova was usually Vestfrost.

    Chris.

    #133112
    Flyman
    Participant

    Re: scandinova uff 238w

    Defrost it completely then move the defrost sensor about an inch further back. The element only runs along the front of the evaporator so they sometimes do not defrost right at the back where the fans are. Also hook a metal strip over the element and drop down towards the drain hole to stop it freezing up. 🙂

    #133113
    stu123
    Participant

    Re: scandinova uff 238w

    chears chaps like the old scandi then will book a calland let u know