Hoover Condenser Dryer Skipping to cool down cycle

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Hoover Condenser Dryer Skipping to cool down cycle

Viewing 8 posts - 1 through 8 (of 8 total)
  • Author
    Posts
  • #92368
    codlets
    Participant

    Going out to a Hoover condenser model DNC D813BB-80 tomorrow, the customer says that every cycle she puts it on displays the correct time but once the start button is pressed it immediately skips to the last 8 minutes, and starts up, but with no heat, so i presume its skipping straight to the final cool down cycle. No error codes displayed
    Anyone had this before ?

    Leon

    #451080
    kaibart
    Moderator

    Re: Hoover Condenser Dryer Skipping to cool down cycle

    Only things to check are heater and front ntc

    #451081
    codlets
    Participant

    Re: Hoover Condenser Dryer Skipping to cool down cycle

    Thanks Yes it was the heater.

    #451082
    codlets
    Participant

    Re: Hoover Condenser Dryer Skipping to cool down cycle

    Update, its still doing the same, although its displaying error code E14 after a few minutes, the original heater was fine, and so were the stats. So i’m guessing a relay on the pcb sticking ??

    #451083
    kaibart
    Moderator

    Re: Hoover Condenser Dryer Skipping to cool down cycle

    See attached file for error e14 kai

    #451084
    codlets
    Participant

    Re: Hoover Condenser Dryer Skipping to cool down cycle

    Thanks. Going back tomorrow

    #451085
    codlets
    Participant

    Re: Hoover Condenser Dryer Skipping to cool down cycle

    Final update: it was the board !

    #451086
    keithwilliams
    Participant

    Re: Hoover Condenser Dryer Skipping to cool down cycle

    just replaced relay on a hoover board today. i do one every now and again. sometimes no heat and sometimes constant heat. (bit like beko dishwasher boards.)