Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #92420
    rolf
    Participant

    Hello any pointers appreciated on this. I’ve got to go out to hoover DYN8144D1X.

    Customer says machine starts then after a couple of minutes the whole display will go blank and start flashing with option button 1, 2 and 5 flashing. Then she pauses and starts it and gets it going again. I’m thinking control fascia PCB.
    Any ideas.

    #451243
    kaibart
    Moderator

    Re: Hoover DYN8144D1X

    1st thing do a insulation check as low insulation under 5meg can cause issues normally the heater can cause odd faults 😕

    #451244
    rolf
    Participant

    Re: Hoover DYN8144D1X

    Thanks for that, had a few issues with hoover machines displaying wrong error codes with low insulation. I went out and checked it, insulation was fine on this occasion but one of the little micro buttons was half stuck in so I’ve ordered new top PCB. I noticed 1, 2 and 5 do flash when paused so should hopefully do the trick.
    Thanks.

Viewing 3 posts - 1 through 3 (of 3 total)