    Don’t normally touch commercial but this is a local pub with new landladies with what seemed like a bog standard fault.
    Unfortunately I’ve never worked on 3 phase before and am trying to pick up as this call lingers on.
    Initially one of the fan motor had blown, order motor and replace. Then second old fan motor blew……coincidence., then first new fan motor goes and now no coincidence.
    Testing on the mains block I initially got, from the neutral up, 230v on each pair. Ok, checked all wiring (v. Helpful these comm. manufacturers, sent me the wiring diagram) and went back to mains block…..now getting 83v, 409v,336v.
    The only difference between this v. basic cooker and domestic one is the contactor.
    Any ideas guys…..flummoxed unless it’s a supply fault as lincat man says it could be a reversed neutral

    #451250
    Hollytree_Technical
    Participant

    Re: Eslr9c lincat commercial cooker

    You should be getting:
    About 400V to 415V between Phases
    About 230V between each Phase and Neutral or Earth
    About 0V between Neutral and Earth

    It definitely looks like a supply issue to me.

    #451251
    cornwell40
    Participant

    Re: Eslr9c lincat commercial cooker

    Many thanks.

    #451252
    cornwell40
    Participant

    Re: Eslr9c lincat commercial cooker

    Thanks again for your help. Neutral in switch box was melting when hot.