    Jimmy A
    Participant

    Hi all!
    We got an old washer dryer with fault code 3.
    Cycle is starting and washing is finishing but second washing with softener didn’t happen last two times, just showing 3 and stop . I can override it by switch off and on again and after that can go to spin.
    I don’t have manual and can’t find any info for that model, please give me an advice.
    I have checked the fault codes for other Bosch washer dryer in forum but they don’t help me.
    1. Is not the heater because last time washed on 90degrees and lid was as usual warm.
    2. Is not the pump because is draining for less than 6mins.
    Just after washing is not continue.
    Thanks

    #451379
    Martin
    Participant

    Re: Bosch wft 2800

    It’s a water filling problem. So either the inlet valve is at fault or the water level air chamber is blocked with gunge.

    #451380
    Jimmy A
    Participant

    Re: Bosch wft 2800

    Thanks Martin
    Will check it and revert asap

    #451381
    Jimmy A
    Participant

    Re: Bosch wft 2800

    So don’t know how but just done full cycle without faults.
    As suggested measure with multicet inlet valve- all four solenoids just unplug, measure and connect again nothing wrong found. Also check for gunge all holes were clear no blocking.
    Hope will work without issues again.
    Thanks for help!

    #451382
    Martin
    Participant

    Re: Bosch wft 2800

    Jimmy A wrote:Also check for gunge all holes were clear no blocking.

    I wasn’t referring to the soap dispenser but the air chamber attached to the drum. Often they can have gunge build-up that can cause intermittent errors with water level control.