Hot point fdff1110g error 10

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Hot point fdff1110g error 10

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #93449
    funbobby
    Participant

    Changed the element on this a couple of months ago so doubt it’s failed that quick but getting same code again, do the thermostats go on these?
    Thanks rob

    #454337
    aqualectric
    Participant

    Re: Hot point fdff1110g error 10

    If the wash pump is noisy or worn then the heater may not have the sufficient flow through it and the thermal overload (on the heater itself) will go O/C. Made that mistake myself on a Hotpoint of this style and a Whirlpool with a similar heat / pump design a few years back. Always check the impellor for sideways movement before fitting the heater.

    Hope that helps!

    Steve.

    #454338
    funbobby
    Participant

    Re: Hot point fdff1110g error 10

    Great thanks