Hoover silent pulse inverter DYN9164 D8PX

Home Forums Public Support Forums General Enquiries And Questions Hoover silent pulse inverter DYN9164 D8PX

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #93926
    motsons
    Participant

    Hi All
    My Hoover Silent Pulse inverter washing machine DYN9164 D8PX was working fine till the the cold weather over the winter. The water in the inlet hose froze and meant it expanded, breaking the inlet connection. Water everywhere, but replaced the inlet at the back ok.
    Machine fills, spins, pumps out to a point and then comes up with E03 near the end of the cycle. I have checked the outlet hoses and pump body for debris but all clear.
    Not sure what to do next. Any help much appreciated.

    Regards Stu

    #455926
    andyjawa
    Participant

    An old question but revisited. Anyone else who gets this fault the most likely suspect is the heater as they commonly run to earth feed back through the pcb giving you the no pump out error code which misleads you into thinking it`s the pump fault which it may well be but can also be the heater to part earth.