Home › Forums › Public Support Forums › Help And Support › Dishwasher Help Forum › Burnt electric connection to in line heater element
- This topic has 8 replies, 2 voices, and was last updated 7 years, 9 months ago by
Spider53.
-
AuthorPosts
-
July 18, 2018 at 3:05 pm #94277
Spider53
ParticipantI have a Hotpoint FDW80G (SERIAL No 70116 1309 ) approx 8 yrs old which tripped out the ring main circuit breaker following filling of machine at start of the cycle. There was a smell of electrical burning too but no fault code. After leaving for a while switched back on to see if tripping reoccured, which it didnt and machine pumped out the water too.
Closer inspection revealed the connector block was burnt and melted on one side.
I have previously replaced the heating element a few years ago and machine has been operating fine since.
Any ideas of possible causes and what I need to be testing to identify the fault so I can assess whether or not a repair will be cost effective on a machine of this age would be gratefully received.
CheersJuly 18, 2018 at 6:24 pm #456867electrofix
ModeratorRe: Burnt electric connection to in line heater element
the fault is just a burnt connection
new heater with new terminals crimped onto clean wire
Dave
July 19, 2018 at 7:57 am #456868Spider53
ParticipantRe: Burnt electric connection to in line heater element
But something must have caused it to burn surely? If I just replace it surely the chance is it will happen again?
July 19, 2018 at 9:44 am #456869electrofix
ModeratorRe: Burnt electric connection to in line heater element
bad dirty or faulty connections will cause it to burn.
If an electrical connection is not 100{e5d1b7155a01ef1f3b9c9968eaba33524ee81600d00d4be2b4d93ac2e58cec2d} then the resistance of the joint will get higher. The higher the joint resistance the more heat will be generated in the connectionRemove connection and check joint on the heater. If it’s in any way corroded or contaminated change it. Then as long as new connections are on clean wire t will be ok. You may have to cut the wire back to get at clean copper and if you want to make sure you could solder the wires into the crimp joints
Dave
July 19, 2018 at 4:13 pm #456870Spider53
ParticipantRe: Burnt electric connection to in line heater element
I might struggle to clean this up and the plastic shroud is also burnt / melted.
July 19, 2018 at 4:19 pm #456871electrofix
ModeratorRe: Burnt electric connection to in line heater element
agreed
take it the plug in the picture is not out of the heater as its not burnt
new heater and new terminal’s on clean wire
Dave
July 19, 2018 at 5:13 pm #456872Spider53
ParticipantRe: Burnt electric connection to in line heater element
No the good looking one is on the drain pump! Took connector out to get view of burnt one.
Do you know where I would be able to get compatible female part of the connection to the heater? Also any advice upon whether to get an original part or would OEM part be OK? I fitted an original one last time so that will be to genuine heaters now!July 20, 2018 at 10:35 am #456873Spider53
ParticipantRe: Burnt electric connection to in line heater element
Looks like a genuine part as it is only a few £s more!
Any suggestions where I could get the female end of the electrical connector to replace the burnt one?July 20, 2018 at 12:34 pm #456874electrofix
ModeratorRe: Burnt electric connection to in line heater element
you can fit 2 separate terminal in the heater connection as long a 1 of them is insulated so they cant touch
there are 2 types depending on how you feel about the wire feeding it. If when you strip it back the copper is clean and shiny then normal insulated crimps will work
of the wire looks a bit dodgy then I would use uninsulated crimps. then solder the wire in the crimp to make sure of a good connection. you can then buy insulating covers and cover one of them
insulated crimps
https://shop.ukwhitegoods.co.uk/3051182 … -connectoruninsulated
crimps
https://www.12voltplanet.co.uk/non-insu … g-tab.html
you need 6.3mm 1.5 cable should be okcovers
https://www.12voltplanet.co.uk/rigid-te … minal.htmlchances are Halfords my stock some of them but you will need the correct crimper for each terminal
if you needed to get the correct connector you may be talking about a new wiring harness and weeks waiting for italso I see 2 heaters listed for this range but your should be the later 1800watt (lower then previous one)
gen
https://shop.ukwhitegoods.co.uk/c000740 … er-elementnon gen
https://shop.ukwhitegoods.co.uk/c000740 … er-elementto be honest fit quite a few compatible heaters if there is a big price difference and not had a lot of problems with them
Dave -