Beko DCU 8230 condenser Dryer

Home Forums Public Support Forums Help And Support Tumble Dryer Help Forum Beko DCU 8230 condenser Dryer

Viewing 7 posts - 1 through 7 (of 7 total)
  • Author
    Posts
  • #94485
    Jackes
    Participant

    The dryer bakes the clothes at every setting I have been told that this maybe the NTC thermister The old one has 9.8 ohms reading what should it be ? or should I be Looking else where?Can anybody help please

    #457487
    electrofix
    Moderator

    Re: Beko DCU 8230 condenser Dryer

    which thermistor are you talking about ?
    there are 2 of them
    one on the element and another at the front

    Dave

    #457488
    Jackes
    Participant

    Re: Beko DCU 8230 condenser Dryer

    Dave The one at the front By the condenser

    #457489
    electrofix
    Moderator

    Re: Beko DCU 8230 condenser Dryer

    door NTC 12000 ohms at 25 degrees C

    Dave

    #457490
    Jackes
    Participant

    Re: Beko DCU 8230 condenser Dryer

    Thanks Dave,
    Does that mean my reading of 9.8 at bout 20 degrees is O-K or should I fit a new one? What do you think? I am a building Engineer Hopeless at electrics
    John

    #457491
    electrofix
    Moderator

    Re: Beko DCU 8230 condenser Dryer

    if your reading is correct and assuming you tested it with the wires disconnected then is way out so probably faulty

    Dave

    #457492
    Jackes
    Participant

    Re: Beko DCU 8230 condenser Dryer

    Dave, Thanks will fit a new one
    John

Viewing 7 posts - 1 through 7 (of 7 total)