January 12, 2019 at 11:29 pm #95295
Ste.eir
ParticipantHi first post here, beko dw5410w not filling and no fault lights, checked the bottom tray float no stuck,drain not clogged,drain pump working, no supply to fill valve. Turn on to first proram and does nothing. Can force drain pumo on holding button in and pumps fine. Cant see a level probe or pressure switch just a counter after the fill valve think got to do with salt regen, any help appreciated(im a fridge engineer)
January 13, 2019 at 1:31 am #459943electrofix
Moderatorhave you checked door switch ?
Dave
January 25, 2019 at 8:25 pm #459944Ste.eir
ParticipantHi dave not checked but when start program it does drain first so im assuming it would not if door switch was faulty, i have replaced pcb and flow counter also.hitting a brick wall now
January 25, 2019 at 10:49 pm #459945electrofix
Moderatordon’t assume some machines will still pump with the door open
Dave
January 26, 2019 at 12:43 am #459946Ste.eir
ParticipantDoor switch checked and is ok, im thinking fault is on wiring harness from pcb to fill valve, nothing else holding it out, do you know if these mahines break the neutral,i have 220v to fill valve but no neutral,jumped a neutral and valve energises but obv keeps filling and consequently draining down now,
January 26, 2019 at 1:02 am #459947electrofix
Moderatortry checking the overflow microswitch in the base from memory think that stops the fill circuit when activated
also is correct model no DWD5410W
Dave
January 31, 2019 at 3:22 pm #459948Ste.eir
ParticipantHi Dave model number is DWD5414S checked the microsurgery in the base and that checks out ok, just don’t get a neutral to the fill valve but I am getting a live, haven’t had any luck finding a wiring diagram
January 31, 2019 at 3:31 pm #459949Ste.eir
ParticipantMicroswitch auto correct lol
January 31, 2019 at 8:13 pm #459950electrofix
Moderatorlive is fed to the valve all the time it then gets its neutral from the pcb terminal 7 green wire. the neutral is switched by the board triacs
I would check you have continuity between plug neutral and terminal 2 (Black) Also see if you have continuity between terminal 3 (brown ) and terminal 8 (orange )
do it with the plug off to avoid false readings
if these two do give a continuity reading you could check the neutral feed wire to the valve from terminal terminal 7 (green) to the valveDave
-
AuthorPosts