  • #95550
    asp11
    Participant

    This error points to a failure in either Heater, Drum limiter or Control board

    The heater is fine and I’ve changed both the control board & limiter…. but the fault code is still showing up

    Is there a reset proceedure I can do to clear the eror code please?

    #460716
    whitevanman
    Participant

    dont know if this helps


    STARTING A RESET
    After an alarm or with the appliance at a standstill, press the Functions and Start/Stop buttons and hold them down
    for about 2 seconds, until a beep is heard.
    “P-” appears on the display and the RESET procedure starts.
    At the end of the procedure, “E-” flashes on the display, alternating with the program which was running and has been
    interrupted, if any.
    Depending on the appliance’s status, the RESET command may not be accepted: in this case, open and close the door
    and then repeat the procedure.
    ATTENTION
    If it is not possible to perform the RESET cycle, before calling the After-Sales Service switch the
    appliance off and back on and then try again.

    from here : https://www.manualslib.com/manual/968764/Smeg-Gw1160.html?page=32

    #460717
    kaibart
    Moderator

    Error 4 is water temperature probe is short circuit or interrupted this is from Smeg service handbook