AEG TD inverter Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › AEG TD inverter This topic has 3 replies, 2 voices, and was last updated 7 years ago by electrofix. Viewing 4 posts - 1 through 4 (of 4 total) Author Posts March 14, 2019 at 12:04 pm #95602 electrofixModerator Long Shot went to an AEG condenser TD model T86280 IC pnc 916096791 / 01 found fault of blown inverter board on closer inspection the charge / safety resistor has blown so badly its gone if anyone goes to one in the near future or has one they can open to find the value of R1 I would be grateful Dave March 15, 2019 at 12:57 pm #460863 baronParticipant Don’t worry what resistor you put there (10 to 47 ohms) but verify power switching LNK and diodes even diodebridge. March 15, 2019 at 1:22 pm #460864 electrofixModerator yes was going to guess around 47 ohms or so and change chip but thought I would see if anyone knew correct one. after all resistor is only there to lower cap inflow current on switch on Dave March 16, 2019 at 5:44 pm #460865 baronParticipant electrofix wrote:after all resistor is only there to lower cap inflow current on switch on Dave A little more than that. You can say that he works like a current limiter (fuse) or RLC filter and so on… Author Posts Viewing 4 posts - 1 through 4 (of 4 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In