AEG TD inverter

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #95602
    electrofix
    Moderator

    Long Shot

    went to an AEG condenser TD model T86280 IC pnc 916096791 / 01

    found fault of blown inverter board

    on closer inspection the charge / safety resistor has blown so badly its gone

    if anyone goes to one in the near future or has one they can open to find the value of R1 I would be grateful


    Dave

    #460863
    baron
    Participant

    Don’t worry what resistor you put there (10 to 47 ohms) but verify power switching LNK and diodes even diodebridge.

    #460864
    electrofix
    Moderator

    yes was going to guess around 47 ohms or so and change chip but thought I would see if anyone knew correct one.

    after all resistor is only there to lower cap inflow current on switch on

    Dave

    #460865
    baron
    Participant

    electrofix wrote:after all resistor is only there to lower cap inflow current on switch on
    Dave

    A little more than that. You can say that he works like a current limiter (fuse) or RLC filter and so on…

Viewing 4 posts - 1 through 4 (of 4 total)