Neff dishwsher. E19 Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Neff dishwsher. E19 This topic has 2 replies, 2 voices, and was last updated 6 years, 10 months ago by clockworkone. Viewing 3 posts - 1 through 3 (of 3 total) Author Posts May 27, 2019 at 3:42 pm #95917 clockworkoneParticipant Reposting due to incorrect model no. Neff d/w S513k60x1g/04. Press start, relay clicks and E19 comes up. Anyone got any ideas. May 28, 2019 at 12:49 am #461726 qasParticipant Fault description for E19 is “Dispenser fault / Heat exchanger valve fault” if that helps at all. Suggestions are check resistances of these parts and wiring between them and the module. May 28, 2019 at 7:44 am #461727 clockworkoneParticipant Many thanks qas. Author Posts Viewing 3 posts - 1 through 3 (of 3 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In