Miele F2 alarm

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #96531
    G-howes
    Participant

    Looking for some advice, I have a Miele Fridge Freezer and I’ve been getting a continuous F2 alarm. I did some research and changed the evaporator sensor and restarted the unit.
    after about an hour of being powered back up the F2 alarm had returned.
    is the anything else I can check/change of is it time to call a Miele engineer.
    thanks in advance.

    #463730
    Tony R
    Participant

    Which evaporator sensor did you change ? hopefully the fridge one, I would suggest you check your connections on the new sensor, if you have replaced the correct one, very rare to have a faulty new sensor, but is possible.

    #463731
    G-howes
    Participant

    Thanks for the reply.
    There was only one sensor on the evaporator at the base of the freezer. It was a Miele replacement which comes with a connector block. You done even have to remove the insulation just insert into the plug and push down.

    #463732
    Tony R
    Participant

    I would still check the connections, I know the silicone crimps that come with the sensor and the plastic box, its possible a wire has not been pushed in far enough before it was squeezed to make the connection

    #463733
    G-howes
    Participant

    I think you might of been right with your first comment. I have used the sensor from the freezer evaporator which I removed and replaced with the new part and swapped it with the one in the fridge (which I didn’t know was there) and powered back up. As yet no F2 alarm.
    fingers crossed
    thanks for your assistance