Lamona HJA8511 – Soap Drawer Leak

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Lamona HJA8511 – Soap Drawer Leak

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #96637
    Hollytree_Technical
    Participant

    Hi All

    This machine has got an intermittent problem that I have yet to see in person (even after watching through a couple of washes) but have been sent a couple of videos of it happening.
    It appears that during the fill stage (doesn’t seem to matter which one) the machine will occasionally leak out of the front, this is not from between the soap drawer and control panel but rather from between the control panel and machine front (left hand corner). The customer does not and never has used the soap drawer for detergent, the pipe from the dispenser housing to the drum is not blocked or twisted and I can find no physical damage. I have also checked that the machine is level and without any electrical insulation faults, that it knows its water level and that it is not backing up in the dispenser housing. The videos that I have been sent show that when it does it it is a small trickle of water that comes out (enough to soak a tea towel).
    Is there any known issues with these machines? I have also another customer with a Blomberg WMI7462W20 that is doing the same thing.

    Jem

    #464276
    electrofix
    Moderator

    check the tech site no sign of any bullitins about this

    have got one myself that’s leaking from the joint between top and bottom. got a new outer box but not fitted yet

    Dave

    #464277
    Hollytree_Technical
    Participant

    Well I fitted a new dispenser and draw just over a week ago and it appears to have cured this one though I still can’t see anything wrong with the old one.

    Jem

    #464278
    electrofix
    Moderator

    the one I had stopped leaking with new box

    cant see fault with old box either

    Dave

    #464279
    kaibart
    Moderator

    I’m changing alot of of dispensers and dispenser draws on these bekos main fault with them is people over dosing on a quick wash they leak due to the agitation of drum as it goes into rinse if it leaks on test cycle then the dispenser and draw I change and have never had a recall