Neff C54L70NOGB/01 E305

Viewing 15 posts - 1 through 15 (of 16 total)
  • Author
    Posts
  • #96995
    snig
    Participant

    Microwave sometimes fickers and goes blank after 15 – 20 seconds and sometimes reads E305. Intermittant fault !!!
    Changed main pcb and initially seemed ok but now doing it again. Anyone know what fault code refers to ???

    #465748
    electrofix
    Moderator

    from what found online seem to be a communication error between the 2 boards

    search google for Bosch error e305 as they are the same unit

    Dave

    #465749
    snig
    Participant

    Further info; have found if i have a decent load in mw its ok but if just a cup of water it goes off after 10 – 20 seconds ? doesnt sound like comm error as that would likley be more consistant ?

    #465750
    electrofix
    Moderator

    that almost sounds like leaking microwave energy in the control panel

    Dave

    #465751
    snig
    Participant

    My thinking now is possibly magnetron breaking down when low load in the oven, however ,would that cause display to faulter,possiblly ?
    Unfortunatley i did my microwave training with the local electricity board long before inverters came in, but i assume they only do the job of the transformer ?

    #465752
    electrofix
    Moderator

    correct no difference apart from invertors can do more precise power control without turning the mag on and off all the time

    I would run it with the case off, with a leak detector in my hand and see if it does it then. With the case open and leaking waves can escape

    Dave

    #465753
    snig
    Participant

    if its leaking i guess that would be mag fault ?

    #465754
    electrofix
    Moderator

    snig wrote:if its leaking i guess that would be mag fault ?

    very likely

    Dave

    #465755
    snig
    Participant

    AGGGH ! customer wanted it doing so changed magnetron. On 10th time of testing it did it again. Can only assume inverter board as its about all i haven’t changed ??? This job just got very expensive

    #465756
    electrofix
    Moderator

    I assume you are not buying the mag etc from Neff as it would get expensive if you did that

    anyway the mag is reusable as there are lots of these units about

    Dave

    #465757
    snig
    Participant

    electrofix wrote:I assume you are not buying the mag etc from Neff as it would get expensive if you did that

    anyway the mag is reusable as there are lots of these units about

    Dave

    No, and luckily had quoted customer for both but they wanted to go ahead anyway as new ones didn’t match their oven !
    Just starting to loose confidence with it, don’t think i’ve ever had any appliance cause me so much trouble

    #465758
    electrofix
    Moderator

    I am not convinced that a mag or invertor can cause the 305 fault. done lots of these but have never seen this fault before or after

    Dave

    #465759
    snig
    Participant

    electrofix wrote:I am not convinced that a mag or invertor can cause the 305 fault. done lots of these but have never seen this fault before or after

    Dave

    Must admit i’m not sure myself, however it is deffinatley load related and works perfectley with a good sized load in the oven. I will double check connection between boards but i have already had it out once and could find nothing wrong. If you can think of anything else i could check i would be MOST grateful

    #465760
    snig
    Participant

    just to add, when it goes off screen goes blank, then comes back on with time clock reset to zero. time then needs to be reset ( not cook time, actual clock )

    #465761
    electrofix
    Moderator

    have you run it with volt meter connected to the mains connection?

    was wondering if you had a fault mains supply

    Dave