Hotpoint f10 fault heating element has Continuity

Home Forums Public Support Forums Help And Support Dishwasher Help Forum Hotpoint f10 fault heating element has Continuity

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #97068
    Dickyboy07
    Participant

    Hi please help I have a hotpoint Aquarius fdl570p.r and six months ago it would stop working mid cycle and l2 and l4 would start to flash after a bit of online research I found it was an f10 fault which said it was the heater element ,so after Checking the heater element I found it had no continuity across the element so I replaced it .all was fine until last week , it is now again stopping mid cycle and l2 and l4 are flashing again so I checked the new heater element for continuity across it , it seems fine now I’m at a loss at what I should do next
    and help would be greatly appreciated please thank you
    regards Richard

    #465982
    electrofix
    Moderator

    I would check the wiring back to the board and then relay on the board that controls the heater. look of bad joints on the pcb around the relay legs

    Dave

    #465983
    Dickyboy07
    Participant

    Thankyou I will try that