    Hi All,

    In need of help. Last week my dishwasher decided to give up the ghost on me. It sometimes decides to try and run then cut out after several minutes. I’m assuming that the internal water level is triggering the safety cut out mechanism.

    I’ve emptied out the sump multiple times and checked the filter. Removed the pump latch and checked the impellars to check they are running freely, and today I swapped out the waste water pump. Still no joy.

    Any ideas would be appreciated before I have to purchase a new machine.

    #466013
    electrofix
    Moderator

    is the check water light coming on ?

    Dave

    #466014
    Garry Howe
    Participant

    Hi Dave,

    Yes, the check water light is coming during the cycle, or at least it was. I’ve been through the manual and checked everything I can, kinked hose, water pressure etc etc.

    Thanks.

    #466015
    electrofix
    Moderator

    As the machine takes on water its counted in by a small switch. These switches fail and if the unit senses that pulses from the switch are not regular it aborts the programme and pumps out

    Dave

    #466016
    Garry Howe
    Participant

    Dave, would this cause the pump to cut out also. When the machine stops, the sump plus an additional quantity of liquid remains?

    #466017
    electrofix
    Moderator

    no it should not,pump should still function

    Dave

    #466018
    Garry Howe
    Participant

    Dave, is there any process of elimination I can go through to pinpoint the issue?

    #466019
    electrofix
    Moderator

    my first job is to check it will pump out

    when you select a new programme the first thing it does is pump out. so add a couple of pints of water, select a new programme ( you may have to cancel the prog first if one is half way through) then see if it pumps out that water