Beko DW not pumping

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #97235
    pmb
    Participant

    Hi I am having problems with a Beko made Lamona LAM8603 which will only send power to the drain pump if the anti flood switch is operated. It drains well when this is done. It will fill and circulate if you set a cycle. I tried replacing the PCB but it’s still the same. It’s going to be a pain to pull out as it’s feet are in torn Lino. Has anyone come across this problem before?
    Thanks, Darren

    #466625
    Hollytree_Technical
    Participant

    Have you checked for a broken wire in the door hinge? I was looking at a diagram for a similar machine and it looks like the pump is switched on the neutral side by KN2 pin 7 (Live comes to it via the door switch).
    The antiflood switch provides an alternative route for the neutral without having to go back to the control board.

    Jem

    #466626
    pmb
    Participant

    Thanks a lot Jem, that makes a lot of sense. I’ll let you know how it goes

    #466627
    pmb
    Participant

    Thanks again Jem, the new wiring harness has solved this