got the above fridge- freezer fault is with the fridge it runs for 4days at +2 and freezer at -22 then fridge will jump upto +13 for 2 days then settle it self back down to normal temp. then starts all over again 4 days fine 2 days not and so on any 💡
regards tony
Check the seal on the baffle control housing at the rear wall/ceiling of fridge and also round the cable entry holes.
If the seal is poor cold air passes directly onto the thermistor when the baffle is open. This causes baffle to close too early giving warmer fridge temp than actually set!
have a check of the condenser fan, check if its says ‘thermal protected’ on the back of the fan motor as these are all ways playing up in the summer months and giving temp problems
ok guys this thing is getting on my t**s now.fitted new fan motor and both the thermistors,adjust door checked cable entrys door sear etc etc freezer now on -22 fridge plus 26 wont get could out all any ideas??????????