Hello. This is my first post so apologies if the answer is already on the forum and I’ve failed to find it!
Our Liebherr fridge has stopped working – interior light is still on when door open but compressor not running at any temperature control knob position.
I’ve removed the thermostat (a RANCO K59-L2629) and tested it with a multi-meter. The continuity results are as follows for the three terminals marked 4, 6 & 3 when looking at the rear of the thermostat with terminal 4 on the left, terminal 6 in the centre and terminal 3 on the right.
With control knob off: No connection between any terminal.
With control knob on (any setting): T4-T6 No connection; T6-T3 Connection; T4-T3 No connection.
I think this could indicate a faulty thermostat but just wondered if anybody could confirm this?
Many thanks.