May 31, 2020 at 8:20 pm #97723
fasetester
ParticipantThis machine wont start Door lock clicking flashing door in display checked motor brushes ok checked connections on pcb cant get door lock out to check it wont come out of machine it moves back and forward but wont come out dont want to force it any idea why it does not want to come out
May 31, 2020 at 9:49 pm #469195electrofix
Moderatorsome of the locks get jammed on the front panel trying to get them out
have you tried loosening the front panel?
Dave
June 1, 2020 at 12:05 pm #469196fasetester
ParticipantThanks dave Just after i posted i discovered that dont think it the interlock getting ohms reading between terminal 3-4 200ohms and circuit between 3-5 when locked have to test the rest of thè components to see if i can find the fault
June 2, 2020 at 4:46 pm #469197fasetester
ParticipantWhat is the wiring connections on wmf 740 thè terminals are left to right 3 4 5 which is c L N and does thè interlock run on rejuced voltage or 240v thanks
June 2, 2020 at 7:32 pm #469198murv
ParticipantThis is an instant door lock.
The module sends short pulses of mains across 3-4 to move the lock to locked or the unlocked position.
I would check the motor continuity at the module plug as this checks the wiring and motor + motor plug in one go.
Usually a lock or motor circuit issue but I did have to swap a module on a similar model last week
Murv…
June 2, 2020 at 9:17 pm #469199fasetester
ParticipantThanks murv so you cant test by power it up it dosent work like L N C what causes thè clicking is it a relay on thè pcb and would a open heater cause the fault is always lnterlock motor pcb related fasetester
June 2, 2020 at 10:15 pm #469200murv
ParticipantNot had a heater cause this problem but always worth checking heater and pump continuity.
There are a number of versions of the WMF740 with different electronics and software so not all versions may respond to a fault in the same way.
A triac on the module provides a pulse to lock the door. It then looks for the locked return signal if none then another pulse to try again. After several attempts it throws a door error (assuming not confused by another fault like a motor circuit error)
Murv…
June 3, 2020 at 10:52 am #469201fasetester
ParticipantThanks murv for your help can this machine be put in dianostic mode fasetester
June 3, 2020 at 11:52 am #469202murv
ParticipantSorry, no engineer diagnostic mode available. The manufacturer and some agents can do very detailed tests with their custom diagnostic kit but this is not available to the trade.
The module does do a self diagnostic on start and records a detailed list of any errors in memory. The current basic error code will show on the machine display, in this case ‘door’. Diagnostic software and a serial interface module are needed to access the detailed error list stored in memory.
Murv…
June 3, 2020 at 5:19 pm #469203fasetester
ParticipantThanks murv so in your opinion thè triac is the most likely component to cause this problum if their is no visual damage to the pcb such as blowen tracks or burning fasetester
June 3, 2020 at 5:43 pm #469204electrofix
Moderatorwont be the door lock triac as you said the door lock is clicking. so what is happening is the board is not reconising the door lock has closed.; This could be because the door lock is faulty, the door lock return wire is faulty or badly connected or the board
plus a motor fault. you have checkede brushes, i assume you have checked the harness back to the boardDave
June 4, 2020 at 2:23 pm #469205fasetester
ParticipantThanks murv and dave for your help put motor and interlock back on took of display board to check it found one of the traces with some corrosion give it a scrape put all back togeather and away it went
so this information might help someone else out thanks again fasetester:)
-