Hotpoin IDC85 Intermittent no heat

Home Forums Trade Technical & Spare Parts Forums Hotpoin IDC85 Intermittent no heat

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #98543
    delta01
    Participant

    hi i have changed the stats kit above the heater but still got intermittent no heat are there any other stats hiding anywhere thanks john

    #472769
    kaibart
    Moderator

    No there are none listed on the drawings

    #472770
    electrofix
    Moderator

    there are quite a few dryers with similar model numbers but the one i looked up has a front stat

    part no C00279578

    model i looked up is a mechanical timer

    IDC85UK F068706 869990687060

    Dave

    #472771
    delta01
    Participant

    thanks v much both i will investigate

    #472772
    delta01
    Participant

    hi i cant find another stat but noticed the negative side from the heater goes through the triple micro switch in the float chamber , i previously noticed the pump running when the float was not activated also it sounds a bit weak when depressed so i am going to try a new switch

    #472773
    electrofix
    Moderator

    if you give me the complete model , serial and commercial code can probably find a wiring diagram and possibly a service manual

    Dave

Viewing 6 posts - 1 through 6 (of 6 total)
  • You must be logged in to reply to this topic.