  • #98678
    Geoff1312
    Participant

    Hi Guys,
    Help please!
    Fitted a new grill energy regulator to above range cooker(because the old one had fallen apart, and was tripping electric)
    Now the cooling fan runs in the off position. Have I wired it incorrectly or could there be another fault?
    Please can anyone furnish me with a wiring diagram?
    Many thanks in advance
    p.s. The energy regulator I fitted has the same diamond H reference number i.e. 48ER101C1P but has one less tag at position 4
    Geoff1312

    #473338
    tash
    Participant

    i can’t help you but did have a similar problem with a 48 regulator wire for wire exchange for a 43 but had a live feed to the cooling fan in off position. never did resolve it

    #473339
    electrofix
    Moderator

    belling tech almost impossible at the moment as their tech site has been off for some time

    this any use if you have not seen it ?

    https://www.ukwhitegoods.co.uk/forums/forum/trade-member-forums/trade-technical-spare-parts-forums/trade-technical-enquiries/12445-diamond-h-wiring-reference

    dave

    #473340
    Geoff1312
    Participant

    Thanks Dave, I’ve seen this if i could get a diagram i could identify the cooling fan cable and hopefully sort it .

    #473341
    Geoff1312
    Participant

    Tash / thanks for your reply , what did you do?

    #473342
    tash
    Participant

    the old switch was working just full on. she was happy to leave it that way

    #473343
    electrofix
    Moderator

    has it got a pcb to control the fan
    if yes all you need to find is the trigger wire from the regulator to the board

    Dave

    #473344
    Geoff1312
    Participant

    Hi Dave don’t think it has a pcb fan control but can’t get a parts listing , had to put in a pne to get grill reg number. If i could find the fan control contact i could probably sus it out . If it has a pcb control it’s ok cos if i remove link wire fan stops.
    Regards Geoff

    #473345
    electrofix
    Moderator

    did you take a phot before installation ?

    https://www.sirples.com/images/catalogo_serie_40.pdf

    your should be the same as 43er

    so you should have

    live to P1
    neutral to 4

    element common goes to 2
    neutral should already be on one element
    the other neutral is fed from contact P2

    the only other contacts left are S1 and S2 this can be used for a pilot light or in your case i would guess this is where the fan should be switched

    is above correct model number as i cant see it anywhere ?

    Dave

    #473346
    Geoff1312
    Participant

    Hi Dave , foolishly didn’t take photo . Did double check mod. no. Will have to go back and try again , just thought if I could track down diagram would make things easier as i would have cable colours. I couldn’t find model either but connections managed to find it and old switch is a 43ER101C1 and apparently they are compatible , thanks for your help.
    If it was easy everyone would do it.
    Cheers Geoff.

    #473347
    electrofix
    Moderator

    is there another identical regulator you could look at colours

    Dave

    #473348
    Geoff1312
    Participant

    Sadly no it’s a gas hob. I’ll go back with all this new info and hopefully resolve , may be a faulty switch , fingers crossed thankyou .
    cheers Geoff