    asp11
    Participant

    I seem to be having weird dryer issues at the moment….

    This appeared to be a simple heater change because there was power down to the 3 pink wires going to the heater but no heat

    Fitted the new heater but still no heat….. 3 pink wires from pcb – heater block are fine & there’s 240 to the 2 wires on the end —- could it be the pcb even though its sending 240v down to the heater??

    Ordered a 2nd heater & an NTC for the fan ducting…… but still no heat & still power down to heater —- I tried all sorts of combos with the parts I had but still it’s not heating

    I’m Very confused….. There’s no way 2 heaters are faulty, so it must be something I’m missing ——- ANY HELP PLEASE?

    PNC – 916097657

    #473750
    electrofix
    Moderator

    you have 3 lives so it wont heat

    element is neutral switched

    check your email

    Dave

    #473751
    asp11
    Participant

    I’m not sure what “neutral switched” means Dave?

    I only actually tried the 2 end wires for mains but not the middle one….. but maybe it also had voltage going to it

    The 3 pink wires go directly to the pcb, so logically it has to be the pcb at fault…… but it might be worth going back and trying the diagnostic test?

    #473752
    electrofix
    Moderator

    neutral switched means the live goes directly to the element and the neutral is supplied through the relay on the board

    could be the relay thats faulty, have changed a few of them

    Dave

    #473753
    asp11
    Participant

    Alrighty, thanks Dave