Beko condenser dryer no heat

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Beko condenser dryer no heat

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #99160
    Rograbbit
    Participant

    Beko dtgc8011w prod 7182482670 s/n 18-200180-01 no heat. Cut out on heater and elements ok. Heater thermistor 1.55K at ambient. Front thermistor 19.4K at ambient. Any ideas please.

    #475225
    murv
    Participant

    Beko rear thermistor usually reads about 20K.

    Murv..

    #475226
    electrofix
    Moderator

    have emailed you the service info

    Dave

    #475227
    Rograbbit
    Participant

    Thanks guys for all your help. Will try a heater.

    #475228
    mikewll23
    Participant

    Did a heater cure it, I’ve got a similar issue it just stops after a couple of minutes with tank full light coming on, clothes are damp

    #475229
    Rograbbit
    Participant

    Yes heater cured it. Sorry not on here often now. Hope you cured yours.
    Roger.