  • #99618
    nibbs2710
    Participant

    Hi All, Firstly a big thanks to everyone over the years as i had used quite a lot of infomation available to repair a number of appliances!

    This is the first time posting as the info I need cannot be found.

    Anyone able to tell me what Er 01, Er 02 and Er 12 mean? The dryer is currently into its Beko service recommended 2hr factory reset unplugged time. I got the impression this is a fob off of their part but happy to be corrected! Dryer is 5years old.

    Thanks in advance.

    #477108
    electrofix
    Moderator

    error codes as follows
    Er 01 : Door has opened during Run Mode
    Er 02 : Overflow switch error
    Er 12: Rotary error.

    Dave

    #477109
    nibbs2710
    Participant

    Awesome thanks Dave.

    I’ve just noticed that when running the door open symbol will flash up and the dryer will stop, so I’m thinking that the door ntc or microswitch is faulty.

    I presume the rotary error is motor related or possibly overloading the dryer

    ​​​​​​Pretty sure the overflow error is old.

    #477110
    electrofix
    Moderator

    door sw maybe but not ntc

    dave

    #477111
    nibbs2710
    Participant

    The microswitch appears to be operating correctly. Without pressing the button, I get continuity between 1 and 2, then open circuit when the button is pressed, which gives continuity 1 and 4, open circuit when released.

    Anything else I should be checking while the dryer is apart?